5kVA 230V to 120V/240V Split Phase Transformer

Single phase to split phase transformer rated value 5kVA, equipped with housing and wheels, input voltage AC 230V/240V/480V is available, output voltage 120V/240VAC. Winding material can choose aluminum or copper wire, frequency 50/60Hz.
SKU: CCHN-T-DGS5kVA
30-day Returns
Free Shipping
Delivery date: 6-25 days

5kVA single phase to split phase transformer can convert the primary voltage 230V into 120V/240V(L1, L2, N, L+L=240V, L+N=120V), enclosure protection grade IP20, the sturdy and durable structure makes it an ideal choice.

5 kVA Single Phase to Split Phase Transformer Specifications

Model CCHN-DGS5kVA
Phase Single phase to split phase
Capacity 5 kVA
Primary Voltage 1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage 120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency 50/60Hz
Winding Material Aluminum/Copper wire (Optional)
Work Efficiency ≥95%
Insulation Resistance ≥50 MΩ
Electrical Strength 2000V AC/1 min
Noise ≤35dB (1 meter)
Insulation Grade Grade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling Method Natural or air cooling
Overload Capacity Allow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test 125Hz/800V/min
Transformation Ratio <3%
Air Carrying Current <6%
Impedance Voltage About 6%
Total Losses 10%
Certification CE, ISO
Temperature -15℃~+45℃
Humidity ≤90%RH, without condensation
Altitude <2000m, non corrosive gas and conductive dust
Enclosure Protection Grade IP20
Warranty 12 months
Weight of Aluminium Wire Transformer Open type: 65kg
Protected type: 84kg
Weight of Copper Wire Transformer Open type: 75kg
Protected type: 100kg

5 kVA Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
5 kVA Single Phase to Split Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer Size Copper Wire Transformer Size
Open type: a*b*c=290*300*350mm Open type: a*b*c=300*310*345mm
Mouting size: D*E=150*180mm (aperture: 20*10mm) Mouting size: 190*190mm (aperture: 20*10mm)
Protected type: A*B*C=380*530*560mm Protected type: A*B*C=380*530*560mm

 

Details

Single Phase Isolation Transformer Details

Tips: How to adjust the transformer gear?
When adjusting the transformer gear, according to the output voltage level, adjust the tap switch to the corresponding position.
The steps to adjust the tap changer are:
1. Disconnect the transformer load, open the high-voltage drop-out fuse with an insulating rod, unscrew the protective cover of the transformer tap switch, and place the positioning pin in the neutral position.
2. When shifting gears, adjust the tap switch to the corresponding position according to the output voltage. When the voltage is too low, switch to the low-voltage gear, and when the voltage is too high, switch to the high-voltage gear.
3. After adjusting the gear, use a DC bridge to measure the DC resistance of each phase winding and check whether the DC resistance between the windings is balanced. If the phase-to-phase resistance difference is greater than 2%, it needs to be re-adjusted. Otherwise, the static and moving contacts will generate heat or even discharge due to poor contact and damage the transformer.