10kVA 120V/220V UPS Backup Uninterruptible Power Supply

Uninterruptible Power Supply, 10kVA/8kW, line interactive UPS, provides a reliable battery backup for critical devices like PCs, servers, and networks against power surges and outages. High reliability yet low-cost 10kVA UPS is available with input and output voltages of AC 220V/120V for choice.
SKU: CCHN-UPS-10K
30-day Returns
Free Shipping
Delivery date: 6-25 days

Applications

10kVA/8000 Watts UPS is an uninterruptible power supply to provide emergency power to a load, and it is mainly used in computers, office equipment, test equipment, light systems, safe alarm systems, ray equipment, medical equipment, copy machines, numerical control machine tools, industrial automation equipment, color and drying equipment, Hi-Fi equipment, etc.

10kVA/8000W UPS Specification

Basics Model CCHN-BE-10K
Rated Capacity 10000VA/8000W
Phase Single Phase (L, N, G) * NOT support the split phase (L1, L2 + G) like USA standard.
Weight (kgs) 16
Dimension (mm) 442×190×318
Input Nominal Voltage 208/220/230/240VAC
Input Voltage Range 110-300 VAC (Based on load at 50%), 176-300 VAC (Based on load at 100%)
Frequency Range 46-54 Hz or 56-64 Hz
Power Factor ≥0.99 @ Nominal Voltage (100% load)
Output Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 46-54 Hz or 56-64 Hz
Current Crest Ratio 50 Hz or 60 Hz ±0.1Hz
Harmonic Distortion ≤3% THD (Linear Load), ≤5 % THD (Non-linear Load)
Transfer Time Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency AC Mode 93%
Battery Mode 91%
Battery Standard Model Battery Type 12V / 9Ah
Numbers 16 20
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A/2A
Charging Voltage 218.4VDC ±1% 273 VDC ±1%
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers 16 - 20 (Adjustable)
Charging Current (Max.) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)
Charging Voltage 273 VDC ±1% (Based on 20pcs batteries)
Indicators LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Alarm Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
Environment Humidity 0-95% RH @ 0-40°C (non-condensing)
Noise Level Less than 55dB @ 1 Meter
Management Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser

Note:

1. The UPS input/output configuration is 1-phase (L, N, G) like Europe standard, NOT support the split phase (L1, L2 + G) like USA standard.

2. Batteries that work with this UPS are not included, customers need to match lead-acid battery packs on their own, consult us for battery specifications.

3. If you need other output voltage range, please contact us.

Rear Panel Diagram

Ups diagram 6kl10kl

  1. External battery connector
  2. RS-232 communication port
  3. Intelligent slot
  4. USB communication
  5. Emergency power off function connector (EPO connector)
  6. Cooling fan
  7. Input circuit breaker
  8. Input/ Output terminal (Refer to Diagrams 3 and 6 for the details)

Tips: Troubleshooting UPS - the battery voltage is low but the battery cannot be charged for more than 10 hours.

Judging from the phenomenon, it is the fault of the battery and charging circuit, which can be inspected according to the following procedures.

  1. Check whether the input and output voltage of the UPS charging circuit is normal. 
  2. If the charging circuit has normal input and abnormal output, disconnect the UPS battery to test again. If it is still abnormal, it is the fault of the charging circuit.
  3. If the charging circuit has normal input and output after the battery is disconnected, it indicates that the UPS battery has been damaged because of the long-term charging, long-term placement, and due life period.