Close
Shopping Categories
Search

AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output

Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.
SKU: CCHN-VOS-ACDC500
30-day Returns
Free Shipping
Delivery date: 6-25 days

AC/DC voltage sensor has measuring range of AC/DC 75mV/30V/50V/100V/250V/300V to 500V.

Specification:

Model CCHN-WBV122S01 CCHN-WBV124S01 CCHN-WBV125S01 CCHN-WBV127S01
Shipping weight 1kg
Measuring range of input voltage * AC/DC 0-75mV ~ 0-500V
Short-time overload 2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times
Linear measurement range 0% ~ 120% measuring range
Frequency range ±DC/20Hz ~ 10kHz
Input impedance When Ux>1V, Ri=Ux*10kΩ/V; when Ux≤1V, Ri≥1MΩ
Output signal * DC 0-5V, 0-10V (only for power supply DC 24V) DC 4-20mA, 0-20mA True RMS DC 0-5V, 0-10V (only for power supply DC 24V) True RMS DC 4-20mA, 0-20mA
Power supply * DC 12V±10%, DC 24V±10%
Accuracy 0.5%F.S.
Load capacity 5mA 6V 5mA 6V
Response time ≤250ms
Temperature drift 250*10-6/℃ 300*10-6/℃ 250*10-6/℃ 300*10-6/℃
Static current ≤34mA Output 0-20mA: ≤34mA
Output 4-20mA: ≤38mA
≤30mA ≤40mA
Isolation features Isolation between input and output, output terminals provides power supply
Isolation voltage DC 1.5kV, 1 min
Work temperature -25~+70℃ -25~+70℃ 0~+50℃ 0~+50℃
Storage temperature -25~+70℃ -25~+70℃ -25~+70℃ -25~+70℃
Input/Output isolation capacitance - 6pF (below 1kHz)
Common mode rejection ratio (CMRR) - 160dB (under condition of 50Hz)
Protection class IP20
Mean time between failures >50000h
Housing material Fire-retardant ABS
Wiring Terminal connection
Installation DIN rail (NS35/7.5, NS35/15, EN50022), or screw (M3) fixation

AC/DC voltage sensor 75mV to 500V dimensional drawing (unit: mm):
AC/DC voltage sensor 75mV/100V/250V/300V to 500V dimension
AC/DC voltage sensor 75mV to 500V wiring diagram:
(The left diagram is for voltage output, the right diagram is for current output.)
AC/DC voltage sensor 75mV/100V/250V/300V to 500V wiring
Tips: How to install the voltage sensor?

There are 3 installation methods of voltage sensor:

  1. Pin-welding installation of the circuit board: Make lines on the circuit board, and weld the voltage sensor to the circuit board like a component. Its advantages are small size, light weight, space saving and easy installation.
  2. Screw fixation installation: The voltage sensor is screwed to the bottom of the chassis or a fixed position, and the external connection is through a variety of different terminals. The advantages are very firm and easy to disassemble.
  3. DIN rail installation: There is a standard 35mm wide dovetail groove on the bottom of the voltage sensor, which can be installed at DIN rail. Its advantages are convenient, versatile, and suitable for field work installation.